Specifications |
EM-2 |
Time
delay period |
Programmable from 1 to 99 minutes
|
|
Open
window |
Programmable from 30 seconds to 9 minutes |
|
Connections |
6-pin Hirose connector,
2 pairs of 0.100" connectors |
Programming |
Programmable via optional keypad
(Protected by programming code)
|
Programming options |
Blocking input: Lock is disabled via external mean.
Dual control: Needs two independent means to open the lock.
Bypass control: Needs user key and bypass key to bypass time-delay.
Batteries fails: With motor locked or unlocked.
|
Accuracy |
+/- 1 second per hour.
|
Installation |
Can be installed in any position.
Multi-handed cylinder adjustable by removing one screw.
|
Dimensions without cylinder |
3.30" long x 2.40" high x 1.16" deep
(83.9mm long x 60.9mm high x 29.5mm deep)
|
Weight without cylinder |
1.03 pounds
468 g
|
Mounting holes |
2.625" x 1.625" or 3.5" x 1.625"
(67 x 41 mm or 89 x 41 mm)
|
Battery life |
3 years at 15 min. delay and 6 openings per day
|
Power supply |
3 VDC provided by batteries or AC/DC power supply
|
Operation |
Medeco key or knob operated.
Standard cylinder lenghts: 1/2", 3/4", 1" and 1.25".
|
Bolt configuration |
EM2-1 |
Manual retraction, automatic extension spring loaded square bolt.
|
EM2-2 |
Manual retraction and extension of direct-drive square bolt.
|
EM2-4 |
Manual retraction slam spring loaded bolt.
|
|
|
|
EM2 indicator / power supply boxes |
|
|
Battery Box |
Simple battery box (no indicators). Internal or external mounting.
|
IND-3B-INT |
Extensive battery indicator with leds for time-delay, open-window and low battery. Buzzer indication for open-window. Internally mounted with acrylic shafts for LED indicators.
|
IND-3B-EXT |
Extensive battery indicator with leds for time-delay, open-window and low battery. Buzzer indication for open-window. Externally mounted.
|
9V connector |
Externally mounted 9V connector for emergency power.
|